general information:
The STL50Ex safety temperature limiter is used where ever thermal processes must be monitored and the system must be transferred into a safe operational state in case of fault. If the permissible temperature limit value is reached, or if a fault occurs within the permissible temperature range on the monitoring equipment (sensor break, sensor short-circuit, failure of a component part in the device, fault in the software, failure or
inadmissible value of the supply voltage etc.), the STL50Ex switches off without delay. The alarm contact is activated, the LED ALARM on the front panel and the back-lighting of the display light up, and the error cause is indicated as plain text on the display. In addition, there is a 24 V DC signal present on the terminals 16-17 for an external alarm signal. Alternatively, the device can be reset using an external contact. In addition, the STL50Ex optionally has a programmable analog output with up or downscaling function, as well as a precontact.
inadmissible value of the supply voltage etc.), the STL50Ex switches off without delay. The alarm contact is activated, the LED ALARM on the front panel and the back-lighting of the display light up, and the error cause is indicated as plain text on the display. In addition, there is a 24 V DC signal present on the terminals 16-17 for an external alarm signal. Alternatively, the device can be reset using an external contact. In addition, the STL50Ex optionally has a programmable analog output with up or downscaling function, as well as a precontact.
- useable as temperature limiter/-guard and exhaust gas temperature limiter
- certified according to EN 61508 SIL2
- intrinsically safe input for use with temperature sensors in 0/20; 1/21; 2/22
- limit value and switching hysteresis programmable
- basic accuracy <0.5 %, ±2 digit
- reaction time ≤0.5 s
- 1 relay for safety-relevant temperature limit, forcibly guided
- 1 relay for pre-alarm
- analog output 0/4 to 20 mA; 0/2 to 10 V
- memory function for error message
- operator lock (password protection)
- contact input for external reset
- 24 V DC signal for external alarm message
specifications:
auxiliary energy | |
auxiliary voltage: |
230 V AC ±10 % 115 V AC ±10 % 24 V DC ±15 % |
power consumption: | < 4 VA |
CE conformity: | EN 61326-1: 2013 EN 61326-2-2: 2013 |
ambient conditions | |
operating temperature: | -10°C to +55°C |
storage temperature: | -30°C to +60°C |
relative humidity: | <95 % |
condensation: | not permitted |
vibration: | operation only in vibration less ambient |
input | |
explosion protection: | II (1) G [Ex ia] IIC/IIB bzw. III (1) D [Ex ia Da] IIIC |
approval: | TÜV 07 ATEX 554295 |
Pt100: | -100.0°C to +600.0°C, 3-wire, max. line resistance 4 Ω/each line sensor current <1 mA (no self heating) |
data in case of an error | |
max. no load voltage U0: | 1.4 V |
max. short circuit current I0: | 6 mA |
max. output power P0: | 7 mW |
min. internal resistor R: | 1.6 kΩ (curve trapezoidal) |
explosion protection | |
Ex ia/IIB: | max. external inductivity: 100 mH max. external capacity: 110 μF |
Ex ia/IIC: |
max. external inductivity: 20 mH max. external capacity: 28 μF |
internal capacity: | negligible |
internal inductivity: |
negligible |
|
|
thermocouple |
|
type J: | Fe-CuNi in the range -100.0°C to +800.0°C |
type K: |
NiCr-Ni in the range -150°C to +1,200°C |
type N: |
NiCrSi-NiSi in the range -150°C to +1,200°C |
type S: |
Pt10Rh-Pt in the range 0°C to 1,600 °C cold junction compensation integrated, data in case of an error |
max. no load voltage U0: |
0.7 V |
max. short circuit current I0: | 2 mA |
max. output power P0: | 1.5 mW |
min. internal resistor R: | 5 kΩ (curve trapezoidal) |
|
|
explosion protection | |
Ex ia/IIB: | max. external inductivity: 100 mH max. external capacity: 240 μF |
Ex ia/IIC: | max. external inductivity: 50 mH max. external capacity: 54 μF |
internal capacity: | negligible |
internal inductivity: | negligible |
accuracy: |
<0.5 %, ±2 digit |
temperature coefficient: |
0.01 %/K |
|
|
display: |
graphic LCD display 28 x 64 pixel, with white LCD-backlight |
|
|
output |
|
relay: |
SPDT <250 V AC <200 VA <2 A cos Phi ≥0.7 <250 VDC <80 W <2 A, internal fused 2 A (slow-blow) |
pre-alarm relays: |
SPDT <250 V AC <500 VA <2 A ohmic load;<30 VDC <60 W <2 A |
analog output: |
0/4 to 20 mA burden ≤500Ω; 0/2 to 10V burden > 500 Ω, galvanically isolated, output automatically changing (burden-dependend) |
accuracy (analog output): |
0.4%; TK: 0.01%/K |
|
|
housing |
|
type: |
polyamide (PA) 6.6 , UL94 V-0 TS35 acc. to DIN EN 60715 |
weight: |
approx. 450 g |
connection: |
screw terminals 0.14 mm2 to 2.5 mm2 (AWG 26..14) |
ingress protection: |
IP20, DIN EN 60529, BGV A3 |
For further details p.r.t. data sheet:
instruction manual as .pdf:
Empfohlenes Zubehör | Weitere Artikel
Sicherheits-Thermoelemente | TC 293 (Ex)218,00 EUR |
|
Sicherheits-Thermoelemente | TC 296(Ex)218,00 EUR |
|
Sicherheits-Temperaturbegrenzer | STL 50623,00 EUR |
|
Sicherheits-Widerstandsthermometer | TR 293(Ex)248,00 EUR |
|
Sicherheits-Widerstandsthermometer | TR 296(Ex)248,00 EUR |